The system won't arm
- If arming to level 2, make sure all monitored perimeter doors and windows are closed.
- If arming to level 3, make sure all perimeter and interior sensors are closed.
Panel doesn't turn on
- Check the circuit breaker to be sure the circuit is live.
- Check that the backup batteries are installed correctly and the transformer is plugged in.
- Check for proper wiring at the panel and the transformer.
Power LED is flashing, the trouble light is flashing, and after pressing STATUS the panel announces, "System battery failure."
- Check the circuit breaker to be sure the circuit is live.
- Check that the back-up batteries are installed correctly, the tabs are making contact, the battery bucket wires are connected to the panel, and the transformer is plugged in.
- Check for proper wiring at the panel and the transformer.
Panel announces, "Sensor (sensor #) low battery."
- Replace the sensor's battery.
Smoke sensor beeps once every minute
- Batteries are low. Replace the smoke sensor batteries.
The panel does not respond to sensor activity. There are no alarm, chime, or sensor test sounds
- Check that the sensor battery is installed.
- Check the sensor battery for low voltage. Replace alkaline or lithium batteries, if necessary.
- Program the touchpads into the panel.
Lights controlled by X-10 Lamp Module do not work
- Check that the lamp has a working bulb.
- Confirm the lamp's operation at a working outlet.
- Check that the lamps are plugged into X-10 Lamp Modules and the X-10 Lamp Modules are plugged into outlets that are not controlled by a switch. Relocate to nonswitched outlets, if necessary.
- Check that the panel is powered by the 4-wire line carrier power transformer and not the 2-wire standard Class II power transformer.
- Check that the HOUSE dial on the X-10 Lamp Module matches the house code programmed into the panel.
|